Rokonet Orbit-6 Specifications Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
ProSound
Remote Control and Diagnostic Features
when Installed on Rokonet Systems’ Bus
Remote reading of input voltage level
Measurement of input charge current
Remote speaker current level (when
speaker is active)
Remote battery voltage level
measurement
Initiate battery load test
Programmable strobe flashing
frequency (20 to 60 times/minute)
Adjustable anti-foam attack sensitivity
15
Status LED
Surface Light Technology
(SLT™) Strobe
Vandal-proof
double-skin metal cover
Specifications
Input voltage and current 13.5 to 14.2 VDC, 200mA maximum
Standby current consumption 54mA + battery charge current
Battery charge current 140mA maximum
Operating current (Siren + Strobe) 1A nominal (1.6 A maximum)
Speaker Sound level 106 dBA at 3 meters
Tone frequency 1500-1800 Hz
Strobe light Surface Light Technology SLT™ with 6000 mcd
Strobe lens Polycarbonate
Strobe flash rate 60 times per minute
Backup battery (not supplied) SLA (Sealed Lead Acid) rechargeable, 12V, 2.2 Ah,
UL approved, Size (L x H x W): 178 x 64 x 35 mm
Battery discharge protection Automatic disconnection below 10.5 VDC
Ingress protection IP 34 rating
Operational temperature -25ºC to 70ºC (-13ºF to 158ºF)
Humidity 95% maximum
Housing material Polycarbonate with UV protection
Tamper contact 0.5A, 24V, termination NC or internal EOL resistor
Anti-foam contact 0.1A, 24V, NC termination
Dimensions (H x W x D) 305 x 218 x 116 mm
Weight (without battery) 2.03 kg
Compatibility All control panels
Rokonet systems compatibility 4 wire RS485 bus, up to 300m from main panel
ProSound Features
Long-life SLT™ strobe (patent pending) combined with 106 dBA sounder
Unique anti-foam, anti-drilling and anti-approach protection (patent pending)
UV-treated weatherproof and vandal resistant polycarbonate housing
Double skin with internal metal cover
Simple installation and maintenance
Remote Control and Diagnostics when connected to Rokonet’s systems
Input protected against polarity reversal, interferences and over-voltages
Negative and positive triggering inputs
Auto-recharging battery circuit
Automatic battery disconnection prevents battery deep discharge
Battery enables 36-hour backup or 80 minutes alarm
Wall and cover tampers with internal EOL resistor
Arm/Disarm and alarm memory indications via status LED