ShockTec
41
ShockTec™ with Magnetic Contact
The ShockTec with Magnetic Contact ensure double protection on opening
windows and doors. The detector can be mounted vertically or horizontally, with
the magnetic contact on either side of the detector.
ShockTec with Magnetic Contact Features
Technical Specifications
ShockTec
TM
ShockTec
TM
with Magnetic Contact
Supply voltage 9V –16V DC
Current consumption (typical) 12.5 mA 7.5 mA
Operational temperature -20
0
C to 60
0
C
Maximum humidity 95% non-condensing
Sensitivity setting Dual stage potentiometer
Tri-color LED indicator Orange: Over-sensitive
Green: Alarm & correct calibration
Red: Under-sensitive
Contact rating: Alarm relay 100mA at 24VDC, NC 100mA at 24VDC, NC, Opto relay
Tamper relay 500mA at 24VDC, NC 500mA at 24VDC, NC
Reed relay N/A 100mA at 24VDC, NC
Alarm time 2.5 seconds
Magnetic contact reed relay option
N/A Two reed relays enable locating the
magnet on either side of the detector
Latching modes Any or 1
st
to latch operation modes
Max no. of units on Any Latch loop 80
Max no. of units on 1 st to Latch loop 10
False alarm
protection Digital microprocessor signal processing and noise
reduction with maximum ground plane
Electrostatic discharge No false alarms up to 8kV
RF immunity 40 V/m from 80MHz to 1GHz
Enclosure material Flame retardant ABS
Enclosure dimensions 25x28x95mm 25x28x95mm – detector
10x12x58mm– magnet
Typical Detection Range
Surface Concrete Brick Wall Steel Glass Wood Plywood
Radius 1.5m 2.5m 3m 3.5m 3.5m 4m
ShockTec with Magnetic Contact
Tri-color LED enables accurate and
reliable calibration, with over- sensitive”
and “under-sensitive” indications
Internal magnetic reed switches for
double protection (shock and contact)
saves installation time and cost
Magnet can be mounted on either
side of the detector up to a 20 mm gap
Mounts on frame or glass, vertically
or horizontally
Dual stage adjustment potentiometer
Encapsulated piezo-electric sensor
Cover tamper protection
Modern design with ample wiring
space and hermetic wiring sea
l