e Detection Technologies
(A) (B)
Variable
Pet
Threshold
Intruder
Signal
Level
Pet
Signal
Level
Fixed
Threshold
PIR
Signal
Strength
Figure
2
Frequency /Crossing
Speed of the Beams
Adaptive
Threshold
Fixed Threshold
in conventional
detectores
PIR
Signal
PIR Signal Level Depends
on the Crossing Speed
Figure
3
ACT™ enables superior catch performance by
switching to MW-only mode either when the room
temperature is close to body temperature, or when
a cloaking attempt is recognized. Delivering
exceptionally high detection capabilities, as well as
immunity from false alarms, ACT™ thwarts even the
most sophisticated burglars.
Intelligent Digital Signal Processing
PIR Technology for WatchOUT, Industrial LuNAR, iWISE
and Wireless PIR detectors
Setting the alarm threshold for detectors is a major
challenge for manufacturers. If the threshold is
set too low, the detector will be prone to false
alarms; if set too high, the detector will not be
sufficiently responsive. ROKONET’s Intelligent DSP
provides a real-time adaptation of the threshold
to the speed that the intruder crosses the beams
rather than a factory-fixed threshold, as shown in
Figure 2.
Variable Pet Threshold™ (VPT™)
PIR Technology for WatchOUT, iWISE DT Pet, iWISE Pet,
Zodiac DT Pet, Zodiac Pet and Wireless Pet
ROKONET’s unique VPT™ algorithms – together with
a custom-designed lens – enables detectors to easily
distinguish between intruders and pets, while
ensuring superior catch performance. PIR signal
levels depend on the crossing frequency of the
detection beams. An intruder with a high crossing
frequency (B) may have a lower signal level than a
pet with a lower crossing frequency (A). Using a
constant threshold may result in detecting pets
while ignoring people!
ROKONET’s VPT™ algorithm solves this problem by
measuring the crossing frequency and selecting the
correct threshold level for the alarm. The threshold
is set above the pet signal and below the intruder
level for each frequency, assuring that intruders are
detected while pets are ignored, as illustrated in
Figure 3 above.