Rokonet ORBiT-14 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Installation and Programming Manual
5
Self Monitoring
The ORBIT-Pro has a “watchdog” feature, which periodically and automatically performs a comprehensive self-test
and reports when operating faults are found. The panel also has a Maintenance Mode which, when selected,
performs an active self-check on many of its components. Its Bus Test allows the system to verify the connections
and the operation of all Keypads and Expansion Modules, whose resulting reports, individually displayed as
percentages on the LCD keypad (or via the Upload/Download software), indicate the efficiency of the unit under
test. Results of less than 100% may be due to faulty wiring, poor connections, or component degradation. Such
early detection can help to eliminate the potential problems later on.
The ORBIT-Pro also incorporates “one-man” walk testing capabilities, allowing an installer or technician to check
the operation of each contact and detector which, when tripped, produces audible feedback and is visibly logged at
the keypad from which the test was initiated.
False Alarm Reduction
In conformance with SIA's (the Security Industry Association) standards for deterring false alarms, the ORBIT-Pro
provides the following programmable features:
swinger shutdown
audible/visual Entry/Exit delays
fire alarm verification
dialer delay before an alarm transmission
cross zoning
Synoptic Map
A program running on a PC (under Windows-NT
®
Operating System) and connected to the ORBIT-Pro’s local bus,
provides a graphic display of the whole system.
Forced Arming Zone (Not for UL Installations)
When this option is enabled (on a per-zone basis), the panel can force arming with these zones opened. If a forced
zone is open, the “Ready” LED will blink and the zone will be bypassed at the end of the exit time. If the zone is
closed at any time during the arm period, it will be automatically unbypassed and re-included in the system.
Figure 1-2, on page 6, provides an overview of the ORBIT-Pro’s architecture and capabilities. You may wish to
look this figure over to obtain a “big picture” of the system before continuing.
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 69 70

Comments to this Manuals

No comments