ZONES: ZONE TYPE (cont’d)
Quick Key Item Default Explanation
ZONE TYPE (cont’d)
0 Instant default for
all zones
except
1 and 2
§ usually intended for non-entry/exit doors, window
protection, shock detection (but generally NOT for
motion detectors)
§ causes an immediate intrusion alarm if violated (after
the expiration of the Exit Delay)
0 I+Exit/Entry 1
(Interior+Exit/Entry 1)
---
§ usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
§ if the system is armed to the AWAY (Arm) mode: a
zone(s) so programmed will provide a delay (specified
by Exit/Entry 1) allowing entry within, and exit from, an
armed premises
§ if the system is armed to the STAY mode:
a zone(s) so programmed will be bypassed
2 3 xx
+
E
N
T
E
R
0 I+Exit/Entry 2
(Interior+Exit/Entry 2)
--- § usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
§ if the system is armed to the AWAY (Arm) mode: a
zone(s) so programmed will provide a delay (specified
by Exit/Entry 1) allowing entry within, and exit from, an
armed premises
§ if the system is armed to the STAY mode:
a zone(s) so programmed will be bypassed
IMPORTANT NOTE:
§ for greater security when arming to the “STAY” mode, it
is possible for the user to eliminate the Entry Delay
period associated with any zone(s) classified as
Entry/Exit 1–by pressing the [STAY] key twice in
succession when arming the system
§ in effect, doing so makes it an INSTANT zone during
the “STAY” mode of operation
0 I+Exit(OP)/Entry
(Interior+Exit(OP)/Entry)
---
§ used for an entry/exit door that, for convenience, may
be kept open when the system is disarmed
§ if the system is armed to the AWAY (Arm) mode:
refer to the explanation in Zone Type 03, above
§ if the system is armed to the STAY mode:
the zone will be bypassed
2 3 xx
+
E
N
T
E
R
0 I+Entry Follow
(
Interior+Entry Follower)
--- § generally used for motion detectors and/or interior
(e.g. foyer) doors which would have to be violated, after
entry, in order to disarm the system
§ if the system is armed to the AWAY (Arm) mode: refer
to the explanation in Zone Type 04, above
§ if the system is armed to the STAY mode: the zone will
be bypassed
1 I+Instant
(Interior+Instant)
---
§ usually assigned to motion detectors unaffected by user
movements during the Entry Delay period
§ if the system is armed to the AWAY (Arm) mode:
a violation of this zone causes an immediate intrusion
alarm (after the expiration of the Exit Delay period)
§ if the system is armed to the STAY mode:
the zone will be bypassed
1 UO Trigger --- § used for a device or zone, which, if violated (at any
time) will trigger a previously-programmed Utility
Output, capable of activating an external indicator,
relay, appliance, etc.