65
UTILITY OUTPUT: PARTITION
Quick Key Utility Output Follows Default Explanation
PARTITION
--- § the Utility Output will follow the chosen
Partition Event, selected among those listed
below:
from this display:
§ designate the partition(s) whose READY condition
will activate the chosen Utility Output by using the
[STAY] key to toggle between YES (Y) or NO (,,)
and either the [STAT] or [BYP] keys to move the
cursor left or right, respectively, as you make your
choices the “xx” in the UO=xx designation refers
the number of the UO currently being programmed
after making your selection, press [ENTER]
§ proceed to PATTERN of OPERATION, and
setting the duration of operation.
0
Ready Follow
--- § activates the designated Utility Output whenever
the selected partition(s) is in the READY state;
select by pressing [ENTER]
0
Alarm Follow
--- § activates the designated Utility Output whenever
the selected partition(s) experiences any ALARM;
select by pressing [ENTER]
0
Arm Follow
--- § activates the designated Utility Output whenever
the selected partition(s) is armed to either the
AWAY or STAY mode; select by pressing
[ENTER]
0
Burglary Follow
--- § activates the designated Utility Output whenever
the selected partition(s) experiences a
BURGLARY (intrusion) alarm; select by pressing
[ENTER]
0
Fire Follow
§ activates the designated Utility Output whenever
the selected partition(s) experiences a FIRE
alarm–either when a FIRE zone is triggered, or
when a keypad’s FIRE alarm keys ( [4] and [5] )
are
§ simultaneously pressed; select by pressing
[ENTER]
0
Panic Follow
--- § activates the designated Utility Output whenever
the selected partition(s) experiences a PANIC
alarm– either when a PANIC zone is triggered, or
when a keypad’s PANIC alarm keys ( [1] and [2] )
are simultaneously pressed; select by pressing
[ENTER]
0
Auxiliary emergency
Follow
--- § activates the designated Utility Output whenever
the elected partition(s) experiences a AUXILIARY
EMERGENCY alarm–either when a AUXILIARY
EMERGENCY zone is triggered, or when a
keypad’s AUXILIARY EMERGENCY alarm keys (
[7] and [8] ) are simultaneously pressed; select by
pressing [ENTER]
0
Duress Follow
--- § activates the designated Utility Output whenever
the selected partition(s) experiences a DURESS
alarm (initiated at the keypad); select by pressing
[ENTER]
0
Buzzer Follow
--- § activates the designated Utility Output whenever a
keypad in the chosen partition sounds its BUZZER
during Auto-Arming, Entry-Exit Delays, and alarm
conditions; select by pressing [ENTER]
P=12345678 UO=xx
Y.......
INSTALLER PROG:
3) UO