3) Utility Outputs
By adding one or more Utility Output Expansion Modules to the system, an extensive list of switched output
possibilities become available. After selecting a System Event used to trigger the intended Utility Output, press
[ENTER] to select the desired PATTERN OF OPERATION, and its duration.
The programming parameters found in this section allow you to choose the event that will trigger a selected
Utility Output, along with the manner in which the output will be applied.
With the display showing:
press [ENTER] to begin.
With the display showing:
enter the two-digit number of the Utility Output you wish to program, using a “leading zero” for numbers between 1
and 9 (e.g. 01, 02, etc.) and press [ENTER].
At this time, you’re ready to program the selected Utility Output using the information found in the table below.
Keep in mind that each of the system’s Utility Outputs may be assigned to a single type of event–relating to
activities in one of four major categories.
the System a Zone
a Partition use of a User Code
Quick Key Utility Output Follows Default Explanation
NOTHING
3
disables the selected Utility Output
SYSTEM
--- § the Utility Output will follow the chosen
System Event, selected among those listed
below:
§ after making your selection, press [ENTER]
§ proceed to PATTERN of OPERATION, on page
69.
1
Bell Follow
---
activates when an alarm is triggered
2
No Telephone Line
---
activates when a telephone line problem is detected
3
Communication
Failure
---
activates when successful communication with the
Central Station cannot be achieved
§ activates when a system trouble condition is
detected
§ troubles include those found in the system’s
general operation as well as those unique to an
Expansion Module
§ detectable troubles in this category include:
§ Bell Circuit fault § Fire Loop trouble
§ loss of Auxiliary Power § Phone Line failure
§ 4-wire BUS failure § Clock not set
4
Trouble Follow
---
§ False Code trouble
INSTALL PROG:
3)UTIL OUTPUT ××
SELECT UO NUMBER
UO=01 (0:1)
UO=01 FOLLOWS:
0)NOTHING
INSTALLER PROG: