Rokonet Orbit-6 User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 37
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
Installer Manual
26
Comments on System Controls (Location 30: 2
nd
Digit)
Silent Panic Bell Squawk on Arming 3 Minute Bypass Enabled
If “NO”, the panic alarm
will be AUDIBLE at the
External Sounder and
visual on the keypad.
If “YES”, the panic alarm
will be INAUDIBLE at
the External Sounder
and invisable on the
keypad.
If selected, Bell Squawk on
Arming will produce a brief
confirmation “chirp” from the
system’s external sounder(s)
once the system is armed
and the Exit Delay expires
If selected, 3-Minute Bypass Enabled
bypasses all zones automatically for 3
minutes when power is restored to an
“unpowered” system–to prevent
potential false alarms by allowing time
for the stabilization of motion and/or
smoke detectors
Location: 30 System Controls: (1
st
Digit):
1
st
Digit Loudspeaker/Bell-Siren UO Extender Quick Bypass Quick Arm
0 Bell-Siren No No No
1 Bell-Siren No No Yes
2 Bell-Siren No Yes No
3 Bell-Siren No Yes Yes
4 Bell-Siren Yes No No
5 Bell-Siren Yes No Yes
6 Bell-Siren Yes Yes No
7 Bell-Siren Yes Yes Yes
8 Loudspeaker No No No
9
(default)
Loudspeaker No No Yes
A Loudspeaker No Yes No
B Loudspeaker No Yes Yes
C Loudspeaker Yes No No
D Loudspeaker Yes No Yes
E Loudspeaker Yes Yes No
F Loudspeaker Yes Yes Yes
Location: 30 System Controls: (2
nd
Digit):
2
nd
Digit 3 Minute Bypass
CZ Installation Bell Squawk on
Arm
Silent Panic
0 Disabled No No No
1 Disabled No No Yes
2 Disabled No Yes No
3 Disabled No Yes Yes
**4 Disabled Yes No No
**5 Disabled Yes No Yes
**6 Disabled Yes Yes No
**7 Disabled Yes Yes Yes
8 Enabled No No No
9 Enabled No No Yes
A Enabled No Yes No
B
(default)
Enabled No Yes Yes
**C Enabled Yes No No
**D Enabled Yes No Yes
**E Enabled Yes Yes No
**F Enabled Yes Yes Yes
** New in Ver. 1.3
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 36 37

Comments to this Manuals