Summary of User’s Commands
This page, called a Command
Summary, is intended to give you
brief summaries of common
system operations. More detailed
explanations and related
information can be found within, by
referring to the user manual.
FUNCTION PROCEDURE
System Arming [USER CODE] + [ARM]
Stay Home Arming [USER CODE] + [STAY]
Instant Stay [STAY] + [STAY]
System Disarming [USER CODE]
Duress Disarming [DURESS CODE]
Silencing an Alarm [USER CODE]
Bypassing / Unbypassing a
Zone
[ Q ] + [ 1 ] + [USER CODE ] + [ ZONE NUMBER TO BE
BYPASSED / UNBYPASSED]
Quick Bypassing Zone [ ZONE NUMBER TO BE BYPASSED ] for at least 2 seconds
Reset Smoke Detector(s)
[ Q ] + [ 2 ] + [USER CODE ] + [UTILITY OUTPUT NUMBER
which is responsible for resetting the Smoke Detector]
Utility Output Operation [ Q ] + [ 2 ] + [USER CODE ] + [ UTILITY OUTPUT NUMBER ]
Display Troubles [ Q ] + [ 3 ]
Display Memory [ Q ] + [ 4 ]
Setting/Changing
a User Code
[ Q] + [ 5 ] + [MASTER CODE] + [CODE NUMBER TO BE
SET/CHANGED] + [NEW CODE]
Set Date [ Q ] + [ 6 ] + [ 1 ] + [MASTER CODE] + [MM] [DD] [YY]
Set Time [ Q ] + [ 6 ] + [ 2 ] + [MASTER CODE] + [H][H] [M][M]
*Set Auto Arm Time [ Q ] + [ 6 ] + [ 3 ] + [MASTER CODE] + [H][H] [M][M]
Set Follow-Me Phone No. 1 [ Q ] + [ 7 ] + [ 1 ] + [MASTER CODE] + Phone No. + [ #]
Set Follow-Me Phone No. 2 [ Q ] + [ 7 ] + [ 2 ] + [MASTER CODE] + Phone No. + [ #]
**Set Follow-Me Phone No. 3 [ Q ] + [ 7 ] + [ 3 ] + [MASTER CODE] + Phone No. + [ #]
**Set Follow-Me Phone No. 4 [ Q ] + [ 7 ] + [ 4 ] + [MASTER CODE] + Phone No. + [ #]
Maintenance:
On/Off Buzzer
On/Off Door Chime
*On/Off Audible Kiss-Off
Indication
[ Q ] + [ 8 ] + [MASTER CODE] + [1]
[ Q ] + [ 8 ] + [MASTER CODE] + [ 2]
[ Q ] + [ 8 ] + [MASTER CODE] + [ 3]
Get Event From Event
Logger
[ Q ] + [ 9 ] + [MASTER CODE] + [EVENT NO.]
Test System [ Q ] + [ 0 ] + [MASTER CODE]
LED Trouble
1 Low Battery
2 AC Power Loss
3 Clock Not Set
4 Communication Trouble
Trouble Table
5 Bell Loop Trouble
*New in Version 1.2
**New in Version 1.3
It is necessary to ARM your system to
obtain protection from intrusion.
All other forms of protection,
including fire and 24-hour panic
alarms (i.e. police, fire, and medical)
are always ready to report alarms
and do NOT need to be armed.