Installer Manual
16
Location: 09 Installer Code II Default: 1206
Same as the Installer Code 1, but with a few limitations: It can't modify the "default
code", observe and modify the first installer's codes, modify any MS phone number,
nor observe & modify MS lock code.
Location: 10 Master Code Default: 1234
PURPOSE: to establish the keypad code for the system’s “chief user”; the
Master Code provides the following special privileges:
to enter, modify, and delete the remaining nine User Codes
to set the system's internal clock
to perform certain system functions and tests
Note: the Master Code cannot be seen by the installer through the zone LEDs on the
keypad.
SYSTEM TIME: LOCATIONS 11-13
Location: 11 Exit Delay Default: 030
PURPOSE: to establish the system’s Exit Delay (the interval, in seconds, between
entering a User Code at the keypad and when the system actually arms).
Enter three digits between 001 and 255 seconds
Location: 12 Entry Delay Default: 060
PURPOSE: to establish the system’s Entry Delay (in an armed system, the interval, in
seconds, between the moment an entry door is opened and an alarm is triggered).
Enter three digits between 001 and 255 seconds
Location: 13 Bell Cutoff Time Default: 04
PURPOSE: to set the interval that the system’s external sounder(s) will operate before
it shuts off automatically.
Enter the number of minutes between 01 and 90
INTRUSION ZONE TYPES AND ZONE SOUNDS: LOCATIONS 14-21
Locations 14 through 21 are identical and are corresponding to Zones 1 through 6 or 8
(in the 8-zone keypad), respectively. Each of these locations contains two digits.
the first digit: Contains the number used to represent the Type of Zone desired
the second digit: Contains the number used to represent the sound produced
when in alarm
Note: 1. When using 6 zone keypad the system disregards zones 7 - 8.
2. When using 8 zone keypad, zones 7 - 8 must be connected to an EOL
resister when not in use.
Master Code
Installer Code
Sounder
Cutoff
Entry Delay
Exit Delay